FT I
FT II – FT III
FT USA V2
ANCILLARY EQUIPMENT
CUSTOMER CARE
CREMATORS
FT cremators are not only the most advanced but also the most cost efficient cremators on the market
Reliable systems
A crematorium with an average of 300 ceremonies a year places different demands on a cremator than a crematorium with 2,500 ceremonies. With the FT I, F TII and FT III, FT has used its many years of experience and know-how in the field of international cremations to develop extremely reliable and user friendly systems for all types of crematoriums.
Fully automated cremators with filter technology and continual emissions control are part of our standard range. We guarantee outstanding economic feasibility for all crematoria, regardless of the number of cremations. All our systems are built upon the principles of reliability, innovation, sustainability and (cost) efficiency. And of course the safety of your employees.
Energy consumption as low as possible at all times
To keep energy consumption as low as possible at all times, both the hardware and the computer control of our systems are subjected to continuous development and improvement. With ever increasing energy costs, energy use is more important than ever before.
More information?
If you are exploring the options, or if you want to know more about (requirements for) permits or need help with permit applications, then please contact us at +44 (0) 113 276 88 88 or info@facultatieve-technologies.co.uk. We would be delighted to help or advise you.
SYSTEMS & PRODUCTS
FT I
Specifications
Height: | 3.035 mm over door frame |
Width: | 1.930 mm |
Length: | 3.500 mm |
Weight: | 11.500 kg |
Fuel: | Natural Gas / LPG |
Opening for installation: | 2.400 mm wide x 2.400 mm high |
Capacity: | Up to 500 cremations per year |
Average cremation time: | 90 minutes |
Electrical Characteristics
Combustion air fan: | Up to 1500 m3/h at 20°C, 0.75 kW |
Control System: | 0.75 kW |
Running Electrical Consumption: | 2.2 kW |
Electrical Supply: | 16 Amps (Motor rated) 380-415V, 50/60 Hz, 3 phase Neutral + earth 200-230V, 50/60 Hz, 1 phase Neutral + earth |
Fuel Consumption
Primary Burner ratings: | 250 kW |
Secondary Burner ratings: | 250 kW |
Gas usage typically: | 20m3/h @ 20mbar (excludes pre-heating of cremator) |
LPG usage: | 6.7 m3/hour @ 40 mbar (based on LPG 80% Butane, 20% Propane) (excludes pre-heating of cremator) |
FT II – FIII
The FT II and FT III are the most advanced cremators in the world
Specifications
FT II | FT III | |
Height: | 3.300 mm | 3.300 mm |
Width: | 2.120 mm | 2.150 mm |
Length: | 3.860 mm | 3.860 mm |
Weight: | 12.600 kg | 12.250 kg |
Fuel: | Natural Gas / LPG | Natural Gas / LPG |
Opening for installation: | 2.650 mm wide x 2.650 mm high | 2.650 mm wide x 2.650 mm high |
Daily operation: | Without limit 24 hours/day | Without limit 24 hours/day |
Average cremation time: | 75 minutes | 75 minutes |
Electrical Characteristics
FT II | FT III | |
Combustion air fan: | 2.000 m3/h at 20 °C, 5,5 kW | 2.000 m3/h at 20 °C, 5,5 kW |
Ejector air fan: | 2.000 m3/h at 20 °C, 5,5 kW | 2.000 m3/h at 20 °C, 5,5 kW |
Control System: | 1,5 kW | 1,5 kW |
Electrical Supply: | 50 Amps (Motor rated) 3 x 400 Volts + neutral + earth – 50Hz |
26 amps 380-415 V, 50 Hz, 3 phase, 5 wire, motor rated |
Fuel Consumption
FT II | FT III | |
Primary Burner ratings: | 250 kW | 250 kW |
Secondary Burner ratings: | 300 kW | 350 kW |
Natural Gas usage typically: | 20m3/cremation (excludes pre-heating of cremator) |
20m3/cremation (excludes pre-heating of cremator) |
LPG usage on request
Also available in double end format
Download brochure FT II /FT III Cremator
FT USA V2
- Low price, high quality
- Short installation time
- Compact and quiet
- Fully automatic
- Excellent environmental performance
- Low maintenance, with easy acces to components
Specifications
Height: | 9′-7″ (115″) |
Width: | 5′-4″ (64″) |
Length: | 14′-3″ |
Weight: | 25,000 lbs |
Fuel: | Natural Gas / LPG |
Opening for installation: | 8′ wide x 10′ high |
Capacity: | Up to 500 cremations per year |
Average cremation time: | 90 minutes |
Electrical Characteristics
Combustion air fan: | 1.200 cu.ft/min at 68°F, 5.0 HP |
Control System: | 1.5 kW |
Electrical Supply: | 60 A service 208-230 V, 60 Hz, 1 phase, 4 wire (2 line, 1 ground, 1 neutral) |
Fuel Consumption
Primary Burner ratings: | 750,000 Btu/hr |
Secondary Burner ratings: | 1,250,000 Btu/hr |
Natural Gas usage typically: | 12 cu.ft/min at 8″ Water gauge (excludes pre-heating of cremator) |
LPG usage on request |
For more information please contact info@facultatieve-technologies.co.uk or +44 (0) 113 276 88 88.