FT cremators are not only the most advanced but also the most cost efficient cremators on the market

Reliable systems

Cremators

A crematorium with an average of 300 ceremonies a year places different demands on a cremator than a crematorium with 2,500 ceremonies. With the FT I, F TII and FT III, FT has used its many years of experience and know-how in the field of international cremations to develop extremely reliable and user friendly systems for all types of crematoriums.

Fully automated cremators with filter technology and continual emissions control are part of our standard range. We guarantee outstanding economic feasibility for all crematoria, regardless of the number of cremations. All our systems are built upon the principles of reliability, innovation, sustainability and (cost) efficiency. And of course the safety of your employees.

Energy consumption as low as possible at all times

To keep energy consumption as low as possible at all times, both the hardware and the computer control of our systems are subjected to continuous development and improvement. With ever increasing energy costs, energy use is more important than ever before.

More information?

If you are exploring the options, or if you want to know more about (requirements for) permits or need help with permit applications, then please contact us at +44 (0) 113 276 88 88 or info@facultatieve-technologies.co.uk. We would be delighted to help or advise you.

FT I

Cremators

Specifications

Height: 3.035 mm over door frame
Width: 1.930 mm
Length: 3.500 mm
Weight: 11.500 kg
Fuel: Natural Gas / LPG
Opening for installation: 2.400 mm wide x 2.400 mm high
Capacity: Up to 500 cremations per year
Average cremation time: 90 minutes

Electrical Characteristics

Combustion air fan: Up to 1500 m3/h at 20°C, 0.75 kW
Control System: 0.75 kW
Running Electrical Consumption: 2.2 kW
Electrical Supply: 16 Amps (Motor rated)
380-415V, 50/60 Hz, 3 phase Neutral + earth
200-230V, 50/60 Hz, 1 phase Neutral + earth

Fuel Consumption

Primary Burner ratings: 250 kW
Secondary Burner ratings: 250 kW
Gas usage typically: 20m3/h @ 20mbar
(excludes pre-heating of cremator)
LPG usage: 6.7 m3/hour @ 40 mbar
(based on LPG 80% Butane, 20% Propane)
(excludes pre-heating of cremator)

FT II – FIII

The FT II and FT III are the most advanced cremators in the world

Specifications

FT II FT III
Height: 3.300 mm 3.300 mm
Width: 2.120 mm 2.150 mm
Length: 3.860 mm 3.860 mm
Weight: 12.600 kg 12.250 kg
Fuel: Natural Gas / LPG Natural Gas / LPG
Opening for installation: 2.650 mm wide x 2.650 mm  high 2.650 mm wide x 2.650 mm  high
Daily operation: Without limit 24 hours/day Without limit 24 hours/day
Average cremation time: 75 minutes 75 minutes

Electrical Characteristics

FT II FT III
Combustion air fan: 2.000 m3/h at 20 °C, 5,5 kW 2.000 m3/h at 20 °C, 5,5 kW
Ejector air fan: 2.000 m3/h at 20 °C, 5,5 kW 2.000 m3/h at 20 °C, 5,5 kW
Control System: 1,5 kW 1,5 kW
Electrical Supply: 50 Amps (Motor rated)
3 x 400 Volts + neutral + earth – 50Hz
26 amps 380-415 V, 50 Hz, 3 phase, 5 wire, motor rated

Fuel Consumption

FT II FT III
Primary Burner ratings: 250 kW 250 kW
Secondary Burner ratings: 300 kW 350 kW
Natural Gas usage typically: 20m3/cremation
(excludes pre-heating of cremator)
20m3/cremation
(excludes pre-heating of cremator)

LPG usage on request
Also available in double end format

Download brochure FT II /FT III Cremator

 

FT USA V2

Cremators

  • Low price, high quality
  • Short installation time
  • Compact and quiet
  • Fully automatic
  • Excellent environmental performance
  • Low maintenance, with easy acces to components

Specifications

Height: 9′-7″ (115″)
Width: 5′-4″ (64″)
Length: 14′-3″
Weight: 25,000 lbs
Fuel: Natural Gas / LPG
Opening for installation: 8′ wide x 10′ high
Capacity: Up to 500 cremations per year
Average cremation time: 90 minutes

Electrical Characteristics

Combustion air fan: 1.200 cu.ft/min at 68°F, 5.0 HP
Control System: 1.5 kW
Electrical Supply: 60 A service 208-230 V, 60 Hz,
1 phase, 4 wire (2 line, 1 ground, 1 neutral)

Fuel Consumption

Primary Burner ratings:  750,000 Btu/hr
Secondary Burner ratings: 1,250,000 Btu/hr
Natural Gas usage typically: 12 cu.ft/min at 8″ Water gauge
(excludes pre-heating of cremator)
LPG usage on request

For more information please contact info@facultatieve-technologies.co.uk or +44 (0) 113 276 88 88.